Connecting to the network, Connecting utp cables to dfe modules, Connecting to the network -14 – Enterasys Networks Enterasys Gold Distributed Forwarding Engine 4G4285-49 User Manual
Page 48: Connecting utp cables to dfe modules -14
Connecting to the Network
3-14 Installation
Connecting to the Network
This section provides the procedures for connecting unshielded twisted pair (UTP)
segments from the network or other devices to the 4G4285‐49 and 4G4205‐72
(“
Connecting UTP Cables to DFE Modules
Connecting UTP Cables to DFE Modules
The fixed RJ45 front panel connections of the 4G4285‐49 and 4G4205‐72 are 10/100/
1000 Mbps ports. These ports have internal crossovers, and support automatic‐polarity
sensing when configured for automatic‐negotiation.
If automatic‐negotiation is not activated on a port, use a straight‐through cable when
connecting a workstation to the port. When connecting a networking device to the port,
such as a bridge, repeater, or router, use a crossover cable.
If a port is set for auto‐negotiation, automatic‐polarity sensing is also activated.
Automatic‐polarity sensing eliminates the need for a crossover cable, regardless if the
connection is to another network device or a workstation.
Warning: The DFE module is shipped with a cover over its 48 Vdc Optional Power Input
connector. Do not remove this cover when the DFE module is installed in an N5 chassis.
This cover is removed only when you connect a 48 Vdc power cable from the Enterasys
N-POE Power System.
Advertencia: El modulo DFE es embarcado con una cubierta sobre su conector de poder
opcional de 48 Vdc. No remover esta cubierta cuando el modulo DFE es instalado en un
chassis N5. Esta cubierta debe removerse unicamente cuando se conecta el cable de
poder de 48 Vdc hacia el Sistema de Enterasys de Energia por Cable (Enterasys N-POE
Power System).
Warnhinweis: Im Auslieferungszustand der DFE Module stülpt eine Schutzkappe über
dem 48V Gleichspannungs-Anschluss, die nur dann abgezogen werden darf, wenn ein
Enterasys N-POE Power System angeschlossen wird. Keinesfalls darf diese Schutzkappe
abgezogen werden, wenn das DFE Modul in einem N5 Chassis installiert wird.
Note: If the module is being installed in a network using Link Aggregation, there are rules
concerning the network cable and port configurations that must be followed for Link
Aggregation to operate properly. Before connecting the cables, refer to the Enterasys
Matrix DFE-Gold Series Configuration Guide for the configuration information. For details
on how to obtain manuals, refer to the “
Note: All RJ45 front panel ports on these DFE module support Category 5 Unshielded
Twisted Pair (UTP) cabling with an impedance between 85 and 111 ohms. Category 3
cable may be used if the connection is going to be used only for 10 Mbps.