beautypg.com

Enterasys Networks Enterasys Gold Distributed Forwarding Engine 4G4285-49 User Manual

Page 42

background image

Preparing to Install Module into Matrix E7 or N7 Chassis

3-8 Installation

To install a DFE module into a Matrix E7 or

Matrix N7

chassis, proceed as follows to 

prepare the module for installation.

1.

Remove the blank panel covering the slot in which the module will be installed. All 
other slots must remain covered to ensure proper airflow for cooling. (Save the blank 
plate in the event you need to remove the module.)

2.

Remove the module from the shipping box. (Save the box and packing materials in 
the event the module needs to be reshipped.)

3.

Locate the antistatic wrist strap shipped with the chassis. Attach the antistatic wrist 
strap to your wrist and plug the cable from the antistatic wrist strap into the ESD 
grounding receptacle at the upper right corner of the chassis.

4.

Remove the module from the plastic bag. (Save the bag in the event the module must 
be reshipped.) Observe all precautions to prevent damage from Electrostatic 
Discharge (ESD).

5.

Examine the module for damage. If any damage exists, DO NOT install the module. 
Immediately contact Enterasys Networks. Refer to “

Getting Help

”  on page xviii.

6.

To install a 4G4285‐49 or 4G4205‐72 into a Matrix E7

or

Matrix N7, proceed to 

Installing the DFE Modules into a Matrix E7 or N7 Chassis

” on page 3‐8. For 

Matrix N3

or Matrix N5, refer to “

Installing the DFE Modules into Matrix N3 or 

Matrix N5 Chassis

” on page 3‐11. 

Installing the DFE Modules into a Matrix E7 or N7 Chassis

Before installing a module into a Matrix E7 or N7 chassis, make sure that you refer to 
instruction in 

Preparation

” on page 3‐6.

To install the module, refer to 

Figure 3‐2

 and proceed as follows:

1.

Prepare the chassis as described in “

Installing the DFE Module into a Chassis

” on 

page 3‐5.

2.

Locate the chassis card guides that line up with the slot number in which the module 
will be installed. Make sure the module locking levers are in the open position (top 
and bottom).

Caution: To prevent damaging the backplane connectors in the following step, take care
that the module slides in straight and properly engages the backplane connectors.

Ensure that the top lever lines up with the desired slot number located on the front panel
of the chassis. Refer to

Figure 3-2

.

Precaución: Para evitar que se dañen los conectores del panel posterior en el siguiente
paso, intente deslizar el módulo en forma recta y verifique que se enganche
correctamente en los conectores de panel posterior.
Asegúrese de que la palanca superior esté alineada con respecto al número de ranura
correspondiente ubicado en el panel frontal del chasis. Consulte en

Figure 3-2

.

This manual is related to the following products: