Enterasys Networks Enterasys Gold Distributed Forwarding Engine 4G4285-49 User Manual
Page 67
Using LANVIEW
Enterasys Matrix DFE-Gold Series PoE Module Hardware Installation Guide 4-5
CPU
Off
Power off.
Ensure chassis has adequate power.
Amber
Blinking. DFE module in
process of booting.
None.
Solid. Testing.
If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.
Green
Blinking. Image starts
running.
None.
Solid. Functional.
None.
Red
Solid. Processor in reset.
None.
Green and
Amber
Blinking. Indicates that the
DFE module is in the process
of shutting down.
None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to start the process
of an orderly shutdown.
While in this state, do not remove any
DFE module.
Amber and
off
Alternately (67% on, 33%
off). Indicates that a
shutdown process has
completed. This indication
will remain for 60 seconds
before automatically
restarting.
While in this state, you have 60
seconds to safely remove the DFE
module from the chassis.
RX/TX Indications in Standard Mode
RX
(Receive)
Off
No link. No activity. Port
enabled or disabled.
None.
Green
Solid. Link present, port
enabled, no traffic is being
received by the interface.
None.
Amber
Flashing. Link present, port
enabled, traffic is being
received by the interface.
None.
Red
Blinking. Indicates
collisions. This indication is
only supported on 10/100
ports.
Contact Enterasys Networks for
technical support.
Table 4-1 LANVIEW LEDs (continued)
LED
Color
State
Recommended Action