Figure 4‐2, Recommended shutdown procedure using offline, Reset switch – Enterasys Networks Enterasys Diamond Distributed Forwarding Engine 7KR4297-04 User Manual
Page 48

Overview of DFE-Diamond Module Shutdown Procedure
4-6 Troubleshooting
Recommended Shutdown Procedure Using OFFLINE/RESET Switch
Before pulling a DFE‐Diamond module out of a chassis,
press or tap on its OFFLINE/RESET switch for less than 1 second.
Its CPU LED changes from solid green to blinking between green and amber, indicating that the
DFE‐Diamond module is shutting down. At the end of the shutdown routine, the CPU LED
changes to a 67%/33% sequence of amber/off, respectively, indicating that the module is in a halt
state. At this time it is safe to restart or remove the DFE‐Diamond module from the chassis.
When a controlled shutdown is initiated from the OFFLINE/RESET switch, you have 60 seconds
from the time the CPU starts flashing amber/off until the time the device is automatically
restarted.
Figure 4-2 OFFLINE/RESET Switch
1 OFFLINE/RESET switch
Caution: Do not pull any DFE-Diamond module out of an operating chassis before it has completed
its shutdown routine.
Precaución: No retire los módulos DFE-Platinum del chasis en funcionamiento hasta que no se
haya terminado con la rutina de apagado.
Note: The only safe time to pull a DFE-Diamond module out of the chassis is when the CPU LED is
blinking amber. Otherwise, system operation will be interrupted.