beautypg.com

Module placement and rules, Matrix n3 chassis, module placement, Matrix n7 chassis, module placement – Enterasys Networks Enterasys Diamond Distributed Forwarding Engine 7KR4297-04 User Manual

Page 26: Matrix e7 chassis, Example 1 (figure 3-1, a), Module placement and rules -4, Examples, module placement in matrix e7 chassis -4, Example 1 ( figure 3-1 , a)

background image

Backplane Connections and Installation Rules

3-4 Installation

The DFE FTM bridging modules have a connection to both FTM1 and FTM2 backplanes, which 
enables them to switch frames between the two backplanes and all modules in the 6C107 chassis. 
However, the older first (6x1xx), second (6x2xx), and third (6x3xx) generation modules are still 
managed using their own Local Management and are not subject to management by the 
DFE‐Diamond module management entity.

The Matrix N3 (7C103) and Matrix N7 (7C107) chassis have only FTM2 connections and support 
only DFE‐Diamond modules.

Module Placement and Rules

The DFE series modules can be installed in a Matrix E7, Matrix N1, Matrix N3, Matrix N5, or 
Matrix N7 chassis. When installing the modules into one of these chassis, make sure to consider 
the following placement rules for the appropriate chassis and module mix.

Matrix N3 Chassis, Module Placement

The Matrix N3 chassis slots 1 through 3 will support only DFE‐Diamond modules.

Rule: There are no particular rules for installing DFE‐Diamond modules into a Matrix N3 chassis. 

Matrix N7 Chassis, Module Placement

The Matrix N7 chassis slots 1 through 7 will support only DFE‐Diamond modules.

Rule: There are no particular rules for installing DFE‐Diamond modules into a Matrix N7 chassis. 

Matrix E7 Chassis

Depending on the modules being installed in the Matrix E7 chassis and to help ensure proper 
operation, consider the following examples and rules for module placement in the chassis. 

Figure 3‐1

 shows six examples of chassis module placement. These examples are described below 

along with the applicable module placement rule.

Example 1 (

Figure 3-1

,

A)

Shows the chassis fully populated with DFE‐Diamond modules (7xxxxx). These modules 
communicate with each other via the FTM2 chassis backplane and act as a single switching entity 
with one IP address. The DFE‐Diamond modules are configured using a Command Line Interface 
set of commands.

Rule: DFE‐Diamond modules can be installed in any available chassis slot in the Matrix E7 
chassis. 

Figure 3-1 Examples, Module Placement in Matrix E7 Chassis

7XXXXX

7H4382-49

6X3XX

6X3XX

6X2XX

6X1XX

1 2 3 4 5 6 7

6X1XX

6X2XX

+

6X3XX 6X3XX

1 2 3 4 5 6 7

6X1XX

6X2XX

1 2 3 4 5 6 7

6X3XX

1 2 3 4 5 6 7

7XXXXX

1 2 3 4 5 6 7

6X3XX

6X3XX

6X2XX

7XXXXX

6X1XX

A

E

D

C

B

F

1 2 3 4 5 6 7