Admin config files tab – Cobalt Co9992-4ENC-4K-HEVC Software-Defined Broadcast Encoder User Manual
Page 105

105
The fields in the Firmware Image Management tab are:
Factory Image, Image 1, and Image 2:
These contain version and release date
information for the corresponding firmware images. If no valid image is present, this
field will indicate
No Image
.
Upload Location:
This field contains the location where the image upload will go. The
9992-ENC automatically chooses a location that will not overwrite the currently running
image.
Boot Location:
This field indicates which image will be used in the next boot. If an
image is successfully uploaded through Dashboard, this automatically changes to point to
that image. It can also be manually changed.
Auto-Reboot After Update:
This field controls whether or not the 9992-ENC will
automatically reboot after a successful firmware upload through Dashboard. By default,
the 9992-ENC will
not
reboot after an update. You can upload the firmware at any time,
and reboot later during a maintenance window.
Manual Image Selection:
Select one of the previously uploaded images from the drop-
down list and click the
Reboot
button to make the changes.
Firmware Update Status:
This describes the status of the Firmware running on the
encoder.
Admin Config Files Tab
As you make configuration changes to the 9992-ENC, they are automatically persisted in non-
volatile storage. If you reboot or power-cycle the card, it will come back in the same
configuration.