beautypg.com

System lockout, 97 system lockout – dbx DriveRack VENU360 Loudspeaker Management System User Manual

Page 99

background image

97

System Lockout

This power-up function locks out the VENU360’s front panel controls to prevent unauthorized tampering. The available options
are:

Unlocked

This is the default setting and allows access to all VENU360 functions from the front-panel controls.

Locked

When this option is selected, all front-panel controls will be locked and a “LOCKED” message will appear in the LCD
display whenever any button is pressed or the SELECT wheel is turned.

Locked with AFS Clear

When this option is selected, all front-panel controls will be locked with the exception of the AFS Filter Clear function.
To clear the AFS filters when this option is selected, press the

EDIT

button, select the AFS module to clear using the

SELECT

wheel or

UP

/

DOWN

buttons, press the

SELECT

wheel to enter the AFS module, then press the

SELECT

wheel one more time to clear the filters.

Locked with AFS Clear and Mutes

This option is similar to the “System Locked with AFS Clear” option listed above. When this option is selected, all
front-panel controls will be locked with the exception of the AFS Filter Clear function and output mutes. To clear the
AFS filters when this option is selected, press the

EDIT

button, select the AFS module to clear using the

SELECT

wheel

or

UP

/

DOWN

buttons, press the

SELECT

wheel to enter the AFS module, then press the

SELECT

wheel one more

time to clear the filters.

TIP:

Before enabling any of the above “lockout with AFS clear” options, make sure to enter the AFS modules and set the

CLEAR MODE parameters to the desired setting. This will ensure the correct filter types can be cleared once the front panel
has been locked. See

‘Advanced Feedback Suppression (AFS) Module’ on page 62

for more information on

editing the AFS CLEAR MODE parameter.

To change the System Lockout option:

1�

Press and hold the

RTA

button then power on the VENU360. Keep the button held until the System Lockout menu

prompt appears in the LCD display then release the button.

2�

Turn the

SELECT

wheel to highlight the desired option.

3�

Press the

SELECT

wheel to select the highlighted option.

4�

When prompted, press the

RTA

button to confirm the selection. The VENU360 will boot up and operate according to the

System Lockout option selected. Pressing any button other than the

RTA

button will abort the procedure and maintain

the setting selected prior to entering the System Lockout menu.