beautypg.com

Edit button, Preset recall & store buttons, Mix/route meters & clip indicators – dbx DriveRack VENU360 Loudspeaker Management System User Manual

Page 11: Output meters & limiter threshold indicators

background image

9

8. EDIT Button

Pressing this button will enter Edit mode. Once in Edit mode, the

UP

/

DOWN

buttons and

SELECT

wheel can be used

to select the desired on-screen processing module for editing or copying and pasting. Pressing and holding this button
when in a processing module’s edit menu will jump between the selected column’s processing edit menus, for fast
in-menu navigation of like processing modules. For more information on using Edit mode, see

‘Editing Processing

Module Parameters (Edit Mode)’ on page 43

.

9. PRESET RECALL & STORE Buttons

These buttons are used to store and recall presets. For more information on managing presets, see

‘Managing

Presets’ on page 45

.

10. MIX/ROUTE Meters & CLIP Indicators

These 6-segment LED meters
display the input signal level
strength and available headroom,
and range from SIG (signal present)
to 0 (dBFS). These meters monitor
the signal level at the 1/2/3 bus
points immediately after the input
Mixers/Routers (see

‘DSP Block

Diagram’ on page 118

to see a

diagram of the signal flow). They will
light when the signal level is greater
than or equal to the values shown in
the table to the right.

Input

LEDs

dBFS

+14 dBu

Analog Gain

Setting

+20 dBu

Analog Gain

Setting

+24 dBu

Analog Gain

Setting

+28 dBu

Analog Gain

Setting

0

-0.1

+14.1 dBu

+20.0 dBu

+24.2 dBu

+28.2 dBu

3

-3

+12.2 dBu

+18.2 dBu

+22.2 dBu

+26.3 dBu

10

-10

+5.2 dBu

+11.2 dBu

+15.3 dBu

+19.3 dBu

15

-20

-4.8 dBu

+1.2 dBu

+5.3 dBu

+9.3 dBu

20

-30

-14.8 dBu

-8.8 dBu

-4.7 dBu

-0.7 dBu

SIG

-48

-32.8 dBu

-26.8 dBu

-22.7 dBu

-18.7 dBu

The LEDs located at the top of the Mix/Route meters are clip indicators. When these LEDs light, it indicates that the
VENU360’s inputs are being overdriven – either at the physical XLR input or in the input Mixers/Routers. These LEDs
feature a peak hold function, so they will remain lit for a short period of time after the signal level drops back below
the clip point. The dbx Type IV™ conversion system built into the VENU360 will clamp down on excessively loud input
signals to prevent the A/D converters from clipping. If these LEDs light consistently, check to see if any dramatic gains
are being applied in the VENU360’s input Routers/Mixers. If input Router/Mixer gains are not causing the issue, you
may need to change the analog input clip level settings in the Utility menu (see

‘Utility Menu’ on page 92

for more

information) or lower the output signal level from the sending device.

11. OUTPUT Meters & LIMITER THRESHOLD Indicators

These 6-segment LED meters display the output signal level strength and available headroom and range from SIG
(signal present) to 0 (dBFS). These meters monitor the signal level post the output processing and MUTE buttons and
before the D/A converters. They will light when the signal level is greater than or equal to the values shown in the
following table.

Input

LEDs

dBFS +4 dBu Analog

Gain Setting

+8 dBu

Analog Gain

Setting

+12 dBu

Analog Gain

Setting

+14 dBu

Analog Gain

Setting

+17 dBu

Analog Gain

Setting

+20 dBu

Analog Gain

Setting

+22 dBu

Analog Gain

Setting

0

-0.1

+4.5 dBu

+8.6 dBu

+12.4 dBu

+14.3 dBu

+17.2 dBu

+19.8 dBu

+22.1 dBu

3

-3

+3.1 dBu

+7.2 dBu

+11.0 dBu

+12.9 dBu

+15.8 dBu

+18.4 dBu

+20.8 dBu

10

-10

-3.8 dBu

+0.3 dBu

+4.0 dBu

+5.9 dBu

+8.9 dBu

+11.4 dBu

+13.8 dBu

15

-20

-13.8 dBu

-9.8 dBu

-6.0 dBu

-4.1 dBu

-1.1 dBu

+1.4 dBu

+3.8 dBu

20

-30

-23.8 dBu

-19.8 dBu

-16.0 dBu

-14.1 dBu

-11.1 dBu

-8.6 dBu

-6.2 dBu

SIG

-48

-41.8 dBu

-37.8 dBu

-34.0 dBu

-32.1 dBu

-29.1 dBu

-26.6 dBu

-24.2 dBu