beautypg.com

dbx DriveRack VENU360 Loudspeaker Management System User Manual

Page 65

background image

63

NOTE:

Where applicable, signals sent to the AFS detector for analysis are mono summed. If one of these summed

signals is polarity inverted, AFS will not be able to detect feedback – as the feedback will cancel out before being
analyzed. If you experience problems with AFS not detecting feedback, check the polarity of the signals/cables feeding the
VENU360’s inputs to ensure they have the same polarity.

AFS modules are fixed and are located in the input processing stage. The following section provides a description of each of
the AFS module parameters and how to edit them.

To edit an AFS module:

1. Press the EDIT button.

2. Select an AFS module using the

SELECT wheel and UP/DOWN

buttons. Press the SELECT wheel

to enter the module’s menu.

3. Use the SELECT wheel and UP/

DOWN buttons to navigate the

menu and edit parameters.

TIP:

When in a menu, pressing and holding the

EDIT

button for approximately 2 seconds will advance to the next module

below in the configuration map, wrapping around through the available modules. This allows quick navigation between menus
of a column and improves efficiency when performing repetitive tasks within like modules.

AFS Parameters

AFS [OFF, ON]

Turns the AFS module on and off. If AFS is off, the filters are bypassed and the algorithm is halted (the filters are not
updated). If AFS is on, the filters are active and they are updated according to the currently selected mode (Fixed or
Live).

WARNING!

If AFS is turned on and filters are set (in use), be careful when turning AFS off, as all filters will be

immediately removed from the signal path and sudden feedback could occur. It is recommended that you lower your
mixer output levels before turning AFS off.

CLEAR MODE [LIVE ONLY, ALL]

This parameter selects which filters will be cleared when you perform the clear function. If the LIVE ONLY option is
selected, only the Live filters will be cleared when you perform the clear function and the Fixed filters will be left alone.
When the ALL option is selected, both Live and Fixed filters will be cleared when performing the clear function.