10

The multi-colored threshold LEDs located at the top of the output meters indicate output limiter activity within the
corresponding output channels. The three colored states are:

Green

Indicates the signal level is under threshold and no limiting is occurring.

Yellow

Indicates the signal level is in the OverEasy

®

region and some minor limiting is occurring. This state is only active

when the Limiter’s “OVER EASY” setting is turned on.

Red

Indicates the signal level has exceeded the Limiter’s threshold and full limiting is occurring.

12. COPY/PASTE Buttons

These buttons allow you to copy and paste various parameter settings and processor module types within the VENU360.
See

‘Copying/Pasting Processing Module Settings’ on page 44

,

‘Configuring Mixers/Routers’ on page

28

, and

‘Configuring Processing Module Insert Types’ on page 30

for more information on how to use the

copy/paste functions.

13. RTA Button

Pressing this button will enter the RTA module. See

‘RTA’ on page 89

for more information on the RTA.

14. UTILITY Button

Pressing this button enters the Utility menu, where you can get information about the VENU360’s firmware and network
settings and configure global system settings which dictate how the VENU360 operates. See

‘Utility Menu’ on page

92

for information on the options and parameters available in the Utility menu.

15. MIX/ROUTE MUTE Buttons

Pressing each of these buttons will enable/disable the “MASTER MUTE” parameter inside each corresponding input
Mixer/Router module. When enabled, the signal will be muted prior to the front-panel meters (see

‘DSP Block

Diagram’ on page 118

to see a diagram of the signal flow). The state of these mutes are stored with presets.

16. OUTPUT MUTE Buttons

Pressing each of these buttons will mute the corresponding output channel prior to the limiters and output meters (see

‘DSP Block Diagram’ on page 118

to see a diagram of the signal flow). The state of these mutes are global and

are not stored to presets. However, by default, the state of these buttons will be retained after a power cycle.

The MUTES POWERUP function, available in the Utility menu, lets you configure the VENU360 to always power on with
all outputs muted. See

‘Mutes Powerup’

under

‘Utility Menu’ on page 92

for more information on this feature.

You can also press and hold any MUTE button upon power up to force the VENU360 to initialize with all outputs muted,
see

‘Initialize With Mutes On’ on page 96

for more information on this feature.

NOTE:

All output MUTE buttons are automatically enabled when recalling a preset, applying configuration changes,

and after running the Setup Wizard. This is a safety feature. When you’re ready to audition or use the system, simply
unmute the output channels.