PROTECT MENU
SCREEN SAVER

Reduces the risk of Image Persistence.
NOTE:

• When the screen saver starts, the image aspect is changed to [FULL]. When the screen saver

stops, the aspect will return to the current [ASPECT] setting.

• When the [MOTION] option is set to [ON], these functions are not available: [MULTI PICTURE],

[IMAGE FLIP] (except for [NONE]), [TILE MATRIX], STILL, [ROTATE] and POINT ZOOM.

• If input is set to [DisplayPort1] and the [DisplayPort VERSION] is set to [1.4], this function is

released.

MOTION

Slightly expands the screen image to the pre-set zoom level then moves the image in four directions (up,

down, right, left) at the pre-set interval. Use the

or

button on the remote control to set the time on the

[INTERVAL] slider, and the zoom percentage on the [ZOOM] slider.
NOTE:

If input is a DisplayPort signal 4K (60 Hz) 10bit, this function is deactivated.

POWER ON DELAY

Delays the monitor from turning on for the amount of time set when the POWER ON button is pressed.

DELAY TIME

The delay can be set between 0 and 50 seconds.

LINK TO ID

Links the [DELAY TIME] to the monitor’s ID. This helps to prevent power surges that may occur if all

monitors in a multi-monitor installation were to turn on at the same time. The higher the Monitor ID, the

longer the delay is before the monitor powers on.
For example, if the Monitor ID is 20 and the [DELAY TIME] is 5 seconds, the amount of time that passes

between when the POWER ON button is pressed and when the power actually turns on is 95 seconds.
This allows the 19 monitors in the multi-monitor installation to turn on with 5-second intervals between

each power on.
NOTE:

If the [DELAY TIME] is set to 0 seconds, there will be no extended delay for [LINK TO ID].

The delay time must be 1 second or higher to delay power on.

SECURITY SETTINGS

Sets the security function.

PASSWORD

Input the current password to change the settings in this menu. The default password is 0000.

SECURE MODE

Selects when a security password is required to use the monitor.

START-UP LOCK

The password is required when powering on the monitor.

CONTROL LOCK

The password is required when pressing a button on the display’s button panel or remote control.

CHANGE PASSWORD

Changes the password for the security function.
NOTE:

The factory preset password is [0000].

CURRENT PASSWORD

Enter the current password.

NEW PASSWORD

Enter a new password.

CONFIRM PASSWORD

Enter the new password again to confirm the password change.

LOCK SETTINGS

Prevents the monitor from being controlled by the wireless remote control, the buttons and key on the

monitor, or both. Please refer to

“Locking the Button Controls”

(

page 54

and

page 55

).

ALERT MAIL

When set to [ON] and the monitor is connected to a network, the monitor can send an email message

when an error occurs. The email settings must be configured in the monitor’s HTTP server settings for an

ALERT MAIL to be sent. See

page 69

.

RESET

Resets all SECURITY settings back to factory setting, except for [POWER ON DELAY] and [SECURITY

SETTINGS].