Troubleshooting
This section may help you isolate the cause of a
problem and as a result, eliminate the need to
contact technical support.
The unit cannot be operated
A function
that does not work is assigned to a function
button. When the menu is not displayed, press
the SELECT/ENTER control (page 8) to confirm
the functions assigned to function buttons.
Adjustments and settings cannot be made
Adjustments and settings may not be
possible depending on the input signals and
the status of the unit. See “Input Signals and
Adjustable/Setting Items” (page 11).
The screen becomes dark and the unit turns
off
If the internal temperature of the unit
increases, the screen may become dark and
the unit may turn off.
Check if the ventilation slots or vents are
blocked with something such as dust.
In this case, refer to Sony qualified service
personnel.
Or, if a no input-signal state continues for 60
minutes, the monitor is automatically turned
off by the auto power-off function. To turn on
the monitor, press the
(Power) switch. To
change the settings, see “Auto Power Down”
(page 38) of “System Setting” in the “System”
menu.
Color is not displayed correctly
Check
whether the “RGB/YCC Range” (page 22),
“EOTF” (page 22), “Color Space” (page 22), and
“Transfer Matrix” (page 22) settings under “Ch.
Setting” are set according to the input signal.
Image smearing and/or flicker occur(s)
These may occur if a signal is input in which
a black image and white image are alternately
and repeatedly displayed in every frame on all
or part of the screen, or static patterns are
displayed for long periods of time. Display a
white screen display or a video on the monitor
for a while. For details, refer to “On Burn-in”