beautypg.com

ProSoft Technology MVI56-DFCMR User Manual

Page 15

background image

Start Here

MVI56-DFCMR ♦ ControlLogix Platform

DF1 Interface Module with Reduced Data Block

ProSoft Technology, Inc.

Page 15 of 113

October 20, 2008

5

On the Connected To Go Online dialog box, click the General tab. This tab
shows information about the processor, including the Revision (firmware)
version. In the following illustration, the firmware version is 11.32

1.6.2 Select

the

Slot

Number for the Module

The sample application is for a module installed in Slot 1 in a ControlLogix rack.
The ladder logic uses the slot number to identify the module. If you are installing
the module in a different slot, you must update the ladder logic so that program
tags and variables are correct, and do not conflict with other modules in the rack.

To change the slot number

1

In the Controller Organization list, select the module [1] 1756-MODULE
MVI56, and then click the right mouse button to open a shortcut menu.

2

On the shortcut menu, choose Properties. This action opens the Module
Properties dialog box.