OBJECT
REQUEST
RESPONSE
Obj Var Description
Func
Codes
Qual
Codes
(hex)
Func
Codes
Qual
Codes
(hex)
Data
Size
(bits)
NOTES
2
16-Bit Counter
Change Event
Without Time
129, 130 17, 28
24
Master will process this
variation
3
32-Bit Delta Counter
Change Event
Without Time
40
4
16-Bit Delta Counter
Change Event
Without Time
24
5
32-Bit Counter
Change Event With
Time
88
6
16-Bit Counter
Change Event With
Time
72
7
32-Bit Delta Counter
Change Event With
Time
88
8
16-Bit Delta Counter
Change Event With
Time
72
23 0 Frozen
Counter
Event: All Variations
1
32-Bit Frozen
Counter Event
Without Time
40
2
16-Bit Frozen
Counter Event
Without Time
24
3
32-Bit Frozen Delta
Counter Event
Without Time
40
4
16-Bit Frozen Delta
Counter Event
Without Time
24
5
32-Bit Frozen
Counter Event With
Time
88
6
16-Bit Frozen
Counter Event With
Time
72
7
32-Bit Frozen Delta
Counter Event With
Time
88
8
16-Bit Frozen Delta
Counter Event With
Time
72
30
0
Analog Input: All
Variations
1
06
16
Master will generate this
variation