Dido do power alarm, Dido fault act – PLANET IGS-10020HPT User Manual
Page 581

User’s Manual of IGS-10020HPT
DIDO DO Power Alarm
Description:
Set or show the system digital output0/1 power alarm.
Syntax:
DIDO Do_pwr_alr [first|second] [dc1|dc2] [enable|disable]
Parameters:
first
: Digital Input/Output 0
second
: Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
dc1
: DC power 1
dc2 :
DC power 2
(default: Set or show digital output/fault alarm 0/1 power_fail)
enable
: Enable digital input0/1 function
disable
: Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)
DIDO Fault Act
Description:
Set or show the system fault alarm action.
Syntax:
DIDO Fault_act [port|power] [enable|disable]
Parameters:
port
: port fail
power
: power fail
DI1
: DI1 trigger
DI2
: DI2 trigger
(default: Set or show digital output/fault alarm 0/1 action)
enable
: Enable digital input0/1 function
disable
: Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)
581