beautypg.com

Dido di enable, Dido do act – PLANET IGS-10020HPT User Manual

Page 579

background image

User’s Manual of IGS-10020HPT

DIDO DI Enable

Description:

Set or show the system digital input0/1.

Syntax:

DIDO Di_en [first|second] [enable|disable] [hightolow|lowtohigh]

Parameters:

first

: Digital Input/Output 0

second

: Digital Input/Output 1

(default: Set or show digital input/output first(0)/second(1) select)

enable

: Enable digital input0/1 function

disable

: Disable digital input0/1 function

(default: Set or show digital input/output/fault alarm 0/1 status)

hightolow

: Trigger -> high to low

lowtohigh

: Trigger -> low to high

(default: Set or show digital input/output 0/1 trigger)

DIDO DO Act

Description:

Set or show the system digital output0/1 action.

Syntax:

DIDO Do_act [first|second] [port|power] [enable|disable]

Parameters:

first

: Digital Input/Output 0

second

: Digital Input/Output 1

(default: Set or show digital input/output first(0)/second(1) select)

port

: port fail

power

: power fail

DI1

: DI1 trigger

DI2

: DI2 trigger

(default: Set or show digital output/fault alarm 0/1 action)

579