PLANET IGS-10020HPT User Manual
Page 341

User’s Manual of IGS-10020HPT
Retry Count (1~5)
This column allows user to set how many times system rerry ping to PD. For
example, if we set count 2, the meaning is that if system retry ping to the PD and the
PD doesn’t response continuously, the PoE port will be reset.
Action
Allows user to set which action will be apply if the PD witout any response.
IGS-10020HPT PoE Switch offers 3 actions as following.
PD Reboot: It menas system will reset the PoE port that connected the PD.
Reboot & Alarm: It means system will reset the PoE port and issue an alarm
message via Syslog, SMTP.
Alarm: It means system will issue an alarm message via Syslog, SMTP.
Reboot Time (30~180s)
This column allows user to set the PoE device rebooting time, due to there are so
many kind of PoE device on the market and theyhave different rebooting time. The
PD Alive-check is not a defining standard, so the PoE device on the market doesn’t
report reboots done information to IGS-10020HPT PoE Switch, so user has to make
sure how long the PD will be finished to boot, and then set the time value to this
column.
System is going to check the PD again according to the reboot time. If ou can not
make sure precisely booting time, we suggest you to set it longer.
Buttons
: Click it to save changes.
: Click it to reset configuration which doesn’t to be saved yet.
341