The page includes the following fields:

Object

Description

System PoE Admin
Mode

Allows user enable or disable PoE function. It will causes all of PoE ports supply

or not supply power.

Power Management
Mode

There are five modes for configuring how the ports/PDs may reserve power and

when to shut down ports.

Classification mode: System reserves PoE power to PD according to PoE class

level.

Allocation mode: allows user to assign PoE power to per port.
Consumption mode
: System offers PoE power accordint to PD real power

consumption.

Priority mode: System offers PoE power according to per port priority setting

when power consumption has been over total power budget.

The default PoE management mode is “

Consumption mode”.

Power Supply Budget
[W]

Set limit value of the total PoE port provided power to the PDs.

For

WGSD-10020HP, the available max. Value is 150.

Temperature
Threshold

Allows setting over temperature protection threshold value. It system

temperature was over it then system lower total PoE power budget automatically.

PoE Usage Threshold

Allows setting how much PoE power budget could be limited.

Buttons

: Click to save changes.

: Click to undo any changes made locally and revert to previously saved values.

For

WGSD-10020HP, the total PoE power reservation from Port-1~8 is up to 150W


PD Classifications

A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is

to provide information about the maximum power required by the PD during operation.

Class 0 is the default for PDs. However,

to improve power management at the PSE, the PD may opt to provide a signature for

Class 1 to 4.

The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input

voltages and operational modes.

A PD shall return Class 0 to 4 in accordance with the maximum power draw as specified by

Table 4-16-1.