Avago Technologies MegaRAID SAS 8204ELP User Manual
Page 59

MegaRAID SAS RAID Controller Family
3-9
Copyright © 2005-2007 by LSI Logic Corporation. All rights reserved.
J5
Mode Select
2-pin
connector
If the firmware flashed onto the
board is corrupted, you need to
place a jumper on J5 (this holds the
CPU core in reset), so you can flash
the firmware. Remove the jumper
after you flash the new firmware.
No jumper: This is the setting during
normal operation (Mode 3). This is
the default.
Jumper: This holds the CPU core in
reset (Mode 0).
Note: The card does not function as
a RAID controller if this jumper
is mounted.
J6
IPMI-Style System
Management
SMBUS/I
2
C header
3-pin
connector
Provides support for enclosure
managements.
J7
Cache Write Pending
LED
2-pin
connector
Connector for enclosure LED.
Provides a signal that indicates
when the on-board
cache contains data and a
write from the cache to the
hard drives is pending.
Optional.
J8
LED Drive
Fault Connector
interface
16-pin
(8x2)
jumper
Provides LED interface individually to
eight SAS ports. The LED indicates
a drive fault on particular ports.
Table 3.4
SAS 8304ELP RAID Controller and SAS 8308ELP RAID
Controller – Jumpers and Connectors (Cont.)
Jumper Description
Type
Comments
- MegaRAID SAS 8204ELP (Channel) MegaRAID SAS 8204XLP MegaRAID SAS 8204XLP (Channel) MegaRAID SAS 8208ELP MegaRAID SAS 8208ELP (Channel) MegaRAID SAS 8208XLP MegaRAID SAS 8208XLP (Channel) MegaRAID SAS 8300XLP MegaRAID SAS 8308ELP MegaRAID SAS 8344ELP MegaRAID SAS 84016E MegaRAID SAS 84016E (Channel) MegaRAID SAS 8408E MegaRAID SAS 8480E MegaRAID SAS 8704ELP (Channel) MegaRAID SAS 8704EM2 MegaRAID SAS 8704EM2 (Channel) MegaRAID SAS 8708ELP (Channel) MegaRAID SAS 8708EM2 MegaRAID SAS 8708EM2 (Channel)