Problem and check item

Description

Remedy

(1) Starter does not run or only "click" sound is heard.

1. Checking of

continuity of

wiring

Check S terminal and B terminal

for deformation, looseness,

rusting, or dust sticking. Carefully

check inserting method of the S

terminal.
If not abnormal, set the key

switch to START position while

cranking (no ignition of engine)

and check if voltage is applied to

the S terminal and B terminal of

starter motor.

(+)

(-)

S

KEY SWITCH

B

K

M

(1) When no voltage is applied to the

S terminal and B terminal, check

continuity of the terminals and

key switch and repair or replace

if necessary.

(2) If voltage is applied to the

S terminal and B terminal,

go to "2. Battery checking."

2. Battery

checking

Check battery voltage and

specifi c gravity of battery fl uid.
[Voltage]

Normal value : 12.4 to 12.8V

Limit (charging required)

: 12.4V or lower

Staring limit : 12V (at 20°C)

[Specifi c gravity]

Normal value : 1.22 to 1.29

Limit (Charging required)

: 1.22 or lower

[Service life]

Variance in specifi c gravity

among cell : 0.04 or more

BATTERY

GRAVITY METER

(1) Charge or change the battery when

voltage is lower than 12.4V or

specifi c gravity is lower than

1.22 (at 20°C).

(2) If the wiring and battery are normal,

remove the starter and go to

"3. Checking of pinion operation."

3. Checking

of pinion

operation

Check if the pinion operates or

sound of magnetic switch contactor

is heard.
If the pinion does not operate

or magnetic switch sound is not

heard, check continuity of each coil

of magnetic switch.

(1) If the pinion operates or contactor

sound is heard, step to "4.

Checking

of magnetic switch (1)."

(2) In case of no continuity

Replace the magnetic switch.

(3) When continuity is OK

Step to "4. Checking of magnetic

switch (2)."

4. Checking

of magnetic

switch

(1) Operate the magnetic switch

and check B-M terminals

M

S

B

K

(1) In case of no continuity

Contact continuity failure.

Replace the magnetic switch.

(2) When continuity is OK

Step to "5. Motor checking."

(2) Check the magnetic switch

plunger and bobbin interior for

dust sticking or rusting.

(1) Clean the plunger. If the bobbin

interior is contaminated, replace

the magnetic switch.

5. Motor

checking

Connect the (+) side of the

battery to the M terminal of

magnetic switch and check if the

motor runs.

(+)

(-)

M

(1) If the motor does not run, check

electric circuit inside the motor,

fi eld coil, armature, and brush and