beautypg.com

E 9-23, Age 9-23 – TA Triumph-Adler P-C2660i MFP User Manual

Page 279

background image

9-23

Setup, Registration, and User Management > System Menu

LAN Interface

Restart Network

LDAP Security (Ext. Address
Book)

Select the communication protocol according to the type of security employed by the LDAP
server.

Value

Off: Do not use security employed by the LDAP server.
SSL/TLS: Encryption is applied to any data communication. To enable LDAP security, the
LDAP port may have to be changed according to the server settings. Typically, 636** for SSL/
TLS is well-known LDAP port.
STARTTLS: Encryption is applied to any data communication. Typically, 389** for STARTTLS is
well-known LDAP port.

NOTE: LDAP must be set to [On] in Protocol Detail on page 9-21.

LDAP Security (User Property)

SMTP Security

Select the communication protocol according to the type of security employed by the SMTP
server.

Value

Off: Do not use security employed by the SMTP server.
SSL/TLS: Encryption is applied to any data communication. To enable SMTP security, the
SMTP port may have to be changed according to the server settings. Typically, 465** for SSL/
TLS is well-known SMTP port.
STARTTLS: Encryption is applied to any data communication. Typically, 25** or 587** for
STARTTLS is well-known SMTP port.

NOTE: SMTP must be set to [On] in Protocol Detail on page 9-21.

POP3 Security (User 1)

Select the communication protocol according to the type of security employed by the POP3
server.

Value

Off: Do not use security employed by the POP3 server.
SSL/TLS: Encryption is applied to any data communication. To enable POP3 security, the
POP3 port may have to be changed according to the server settings. Typically, 995** for SSL/
TLS is well-known POP3 port.
STARTTLS: Encryption is applied to any data communication. Typically, 110** for STARTTLS is
well-known POP3 port.

NOTE: POP3 must be set to [On] in Protocol Detail on page 9-21.

POP3 Security (User 2)

POP3 Security (User 3)

*

After changing the setting, restart the system or turn the machine OFF and then ON.

**

You can change the port number using Embedded Web Server RX.

Item

Description

LAN Interface

Specify the settings for the LAN interface to be used.*

Value

: Auto, 10Base-Half, 10Base-Full, 100Base-Half, 100Base-Full, 1000BASE-T

*

After changing the setting, restart the system or turn the machine OFF and then ON.

Item

Description

Restart Network

Restarts the network.

Item

Description

This manual is related to the following products: