Using the Operation Panel

2-72

2

Press

or

repeatedly until Others > appears.

3

Press .

4

Press

or

repeatedly until >Auto Error Clear > appears.

5

Press and display >>Error Clear Timer. The default
setting is 30 seconds.

6

Press [OK]. A blinking cursor (_) appears.

7

Press

or

to increase or decrease the value at the blinking cursor and set the desired time. The

time must be set between 000 and 495 seconds, in 5-second increments. If set to 000, printing will
be continued immediately without any time interval. You can use and to move the cursor right
and left.

8

Display the desired time and press [OK].

9

Press [Menu]. The display returns to Ready.

Finishing

These settings are possible only when the optional finisher is installed on the printer.

Duplex Printing Error Detection Setting

This setting controls whether or not the message Duplex disabled Press GO appears when
label or some other type of paper that is not supported for duplex printing is specified as the paper
type when duplex printing is being performed.

1

Press [Menu].

2

Press

or

repeatedly until Others > appears.

3

Press .

4

Press

or

repeatedly until >Finishing Error > appears.

Ot h er s >

>A u to Er r or >

C l ea r On

>> E rr o r C le ar

T i me r 03 0 s e c.

>> E rr o r C le ar

T i me r 03 0 s e c.

On •

Press [GO] to perform simple printing.

Press [Cancel] to cancel the print job.

Off

Disable duplex printing. (reverts to simplex printing)

Ot h er s >

>F i ni s hi n g >

E r ro r