Pulse width trigger – RIGOL DS1000D User Manual

Page 67

background image

RIGOL

© 2008 RIGOL Technologies, Inc.

User’s Guide for DS1000E, DS1000D Series

2-37

Pulse Width Trigger

Pulse Width Trigger Mode: Pulse trigger occurs according to the width of pulse.
The abnormal signals can be detected through setting up the pulse width condition.

Press Trigger MENU→Mode→Pulse to display the pulse width trigger menu as
follows.

Figure 2- 43 Table 2- 21 The Pulse Width Trigger Menu (page 1/2)

Menu

Settings

Comments

Source

CH1
CH2
EXT
D15-D0

Selects CH1 as trigger signal
Select CH2 as trigger signal
Select EXT TRIG as trigger signal
Select a digital channel in
D15-D0 as trigger source( Only
for DS1000D series)

When

(

+Pulse width

less than)

(+Pulse width

more than)

(+Pulse width

equal to)

(-Pulse width

less than)

(-Pulse width

more than)

(-Pulse width

equal to)

To select pulse condition

Settings

Set required pulse width

This manual is related to the following products: