Pulse Output (PUlse) 
Pulse outputs may be assigned to: rate (RATE); total (TOTAL); grand total (GrTOTAL); 
retransmit (RETRAN); quadrature (QUAD); Modbus PV or math channel (PV); or test (TEST). 
Input Pulse Rate Pulse Output (RATE) 
A pulse rate based pulse output is a factor of the rate display and count (or divisor). The 
rate display is a factor of the input pulses, time base, and the input k-factor. The rate of 
output pulses over one time base (seconds, minutes, hours, days) is defined below in 
terms of input pulses, the input k-factor, and count parameters. 
For example, if the input k-factor value is set to 10, and the count set to 10, one output 
pulse is generated for every 100 input pulses. 
 
Total & Grand Total Pulse Output (TOTAL, GrTOTAL) 
A total and grand total based pulse output is a factor of the associated total and count (or 
divisor). A pulse will be generated for every total accumulation amount equal to the count. 