Maintenance and cleaning

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

ATTENTION:
The frequency with which the smoke discharge

system is cleaned should be determined based on the

type of use that is made of the stove and the type of

installation.
MCZ suggests relying on an authorized service centre

for end-of-season cleaning and maintenance, who

will carry out all of the previously mentioned work

and make a general check of the stove's components.

7.2.2. Shutting the stove down (end of season)

At the end of season, before shutting down the stove, we recommend

completely removing pellets from the hopper with the use of a vacuum

cleaner with an extension.
During periods of disuse, the stove must be unplugged and

placed in a dry place protected from the elements. For greater

safety, especially if there are children around, we recommend

removing the supply cable from the rear of the stove.
Upon re-start, when pressing the main switch (located on the back of

the stove) does not make the control panel display light up, it could

mean that the service fuse needs replacing.
On the rear of the stove there is a fuse holding compartment which is

located underneath the supply socket. Use a screwdriver to open the

fuse-holder compartment and if necessary replace them (3.15 AT

delayed)

7.2.3. Check of internal components

ATTENTION!
The check of the internal electro-mechanical

components must be carried out only by qualified

personnel with technical knowledge of electricity and

combustion.

We recommend that an annual maintenance service is carried out,

preferably under a programmed service contract. The essential part of

this service is a visual and functional check on the internal components:
The following is a summary of the checks and/or maintenance tasks

which are indispensable for the correct operation of the stove.

PARTS / INTERVAL

1 DAY

2-3 DAYS

30 DAYS

60-90 DAYS

1 YEAR

Grate

Ash collection

t

t

Ash drawer

Glass

Lower heat exchanger

Complete exchanger

Smoke duct

Door seal

Air filter

Remote control battery

(if purchased/optional)