PELLET STOVES

Chapter 5

INSTALLATION AND USE MANUAL

page

38

Menu structure

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

Esc Set
< Settings >

Mode:Auto Menu
Temp:22°C Fan:A

Esc Set
< Time and date >

21.0°C 21.04
OFF

Esc It Set
< Language >

Esc Set
< Settings >

Esc It Ok
< Language >

Esc It Ok
< Language >


5.4.2. Automatic mode with AUTO-ECO (panel

display: ON-AUTO ECO)

Activation of this mode is performed through the MENU - SETTINGS -

AUTO ECO-ON.
As for AUTO mode, the desired room temperature is set; when the set

temperature < room temperature condition is reached (room

temperature achieved) the "ECO shutdown T" begins to decrease

(default 10 minutes, changeable within the technical menu by an

authorised MCZ technician). During this phase on the small panel

display remains ON-ECO ACTIVE, but the flame drops automatically by

one power per minute until it reaches P1 and stays there until the

programmed "ECO shutdown T" lapses and if the room temperature is

still achieved, it moves on to the shutdown phase.
ECO stop shutdown follows the normal shutdown procedure, whilst on

the penal the wordings "SHUTDOWN" and "ECO ACTIVE" alternate.
The possibility of adjusting "ECO shutdown T" derives from the

necessity of correct operation in the various environments in which a

stove may be installed and avoiding continuous shutdowns and

lightings in the case in which the room temperature is subject to

constant changes (air currents, low room insulation etc.)
Once the stove shutdown conditions are reached, on the panel the

words "OFF" and “ECO ACTIVE” alternate.