PELLET STOVES

Chapter 2

INSTALLATION AND USE MANUAL

page

14

Theoretical notion for installation

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

2.6. CONNECTION TO THE FLUE PIPE

The flue pipe must have internal dimensions not larger than 20 x 20

cm, or diameter 20 cm. In the event of larger dimensions, or of the

flue pipe being in poor condition (for example cracks, poor insulation,

etc.), it is advisable to fit a stainless steel pipe of suitable diameter

inside the flue pipe throughout its length, right up to the top.

Check with suitable instruments that there is a minimum draught of 10

Pa.

At the bottom of the flue pipe, provide an inspection cap to allow

periodic checking and cleaning, which must be done annually.

Make a gas-tight connection to the flue pipe, using pipes and

connectors as recommended by us.

You must ensure that a windproof cowl should be fitted which complies

with the standards in force.

This type of connection ensures the evacuation of the

fumes even in the event of a temporary power cut.

2.7. CONNECTION TO AN EXTERNAL FLUE WITH

INSULATED OR DOUBLE-WALL PIPE

The external fluepipe must have internal dimensions of minimum

10x10 cm or 10 cm diameter, and maximum 20x20 cm or 20 cm

diameter.

Check with suitable instruments that there is a minimum draught of 10 Pa.

The only type of pipe which is permissible is insulated (double-walled)

stainless steel, smooth on the inside, fixed to the wall. Flexible stainless

steel pipe must not be used. At the bottom of the flue pipe, provide an

inspection cap to allow periodic checking and cleaning, which must be

done annually. Make a gas-tight connection to the flue pipe, using

pipes and connectors as recommended by us.

You must ensure that a windproof cowl should be fitted which complies

with the standards in force.

This type of connection ensures the evacuation of the

fumes even in the event of a temporary power cut.

2.8. CONNECTION TO THE FLUE PIPE

For proper functioning, the connecting pipe between the stove and the

chimney or flue duct must have a slope of not less than 3% in the

horizontal stretches, the length of which must not exceed 2/3

metres, and the vertical distance between one tee connector and

another (change of direction) must not be less than 1.5m.

Check with suitable instruments that there is a minimum draught of 10

Pa.

At the bottom of the flue pipe, provide an inspection cap to allow

periodic checking and cleaning, which must be done annually.

Make a gas-tight connection to the flue pipe, using pipes and

connectors as recommended by us.

You must ensure that a windproof cowl should be fitted which complies

with the standards in force.

This type of connection ensures the evacuation of the

fumes even in the event of a temporary power cut.

0,5 mt.

1

2

3

1) Windproof cowl
2) Flue pipe
3) Inspection

0,5 mt.

2

1

3

1) Windproof cowl
2) Flue pipe
3) Inspection

3-5 %

2 - 3 mt. MAX

0,5 mt.

H

>

1

,5

m

t.

3

2

1

1) Windproof cowl
2) Flue pipe
3) Inspection

This manual is related to the following products: