Safety devices

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

6. SAFETY DEVICES

The stove is fitted with the following safety devices:

SMOKE TEMPERATURE SENSOR.

Monitors the temperature of the smoke, and gives permission for

start-up or shuts the stove down when the smoke temperature

falls below the preset value.

PELLET HOPPER TEMPERATURE SENSOR.

If the temperature surpassed the set safety value, it immediately

halts the stove's operation and to restart it is necessary to wait

until the stove has cooled down

ELECTRICAL SAFETY

The stove is protected against violent surges of current by the

main fuse, which is located on the control panel at the rear of the

stove. Other fuses to protect the electronic boards are to be found

on the boards themselves.

FAILURE OF THE SMOKE EXTRACTION FAN

If the fan stops, the electronic board rapidly shuts off the supply of

pellets and an alarm is displayed.

BREAKDOWN OF THE REDUCTION MOTOR

If the gear motor stops, the stove shuts down and the relative

alarm is signalled

TEMPORARY POWER CUT

If there is a power outage during operation, when the power

comes back on the stove will go into cooling mode and then it will

come back on automatically.

FAILURE TO LIGHT

If during ignition no flame develops, the stove will go into alarm

condition.

TAMPERING WITH THE SAFETY DEVICES IS

PROHIBITED
It is only after eliminating the cause which gave rise to the

intervention of the safety system, that it is possible to relight

the stove and thus reset the automatic operation of the

sensor. To understand which anomaly has occurred, consult

this manual at paragraph 6.1 which explains what to do

based on the alarm message the stove displays.

6.1. ALARM SIGNALLING

Should an operating condition other than that foreseen for normal

stove operation take place an alarm condition is triggered. The control

panel shows the reason for the alarm in progress and by pressing the

info key summarised instructions are given on how to proceed to

restore the stove. The alarm sound signalling is not foreseen for A01

and A02 so that the user is not disturbed if pellets run out during the

night.