POS.14

THERMOSTAT CABLE

5.4.6. Connection to a room thermostat

The room thermostat is not included with the stove

and it must be installed by a specialised technician.

WARNING!
The electrical wires must not be in contact with the

hot parts of the stove.


The stove can also be connected to a room thermostat. The procedure

to follow for the connection of the external thermostat is the following:

 Connect the two wires of the cable which come from the room

temperature to the two free terminals of the connector

(position 14 wiring diagram chap.7). To do this it is

necessary to:

o

unscrew the protective cap of the probe

o

Pass the two wires through the protective cap and

insert them into the hole together with the probe.

o

Pull the two wires to carry out connection to the board

corresponding to terminal 14 (see chap.7)

o

Close the protective cap again.