Safety devices

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

The table below describes the possible alarms signalled by the stove,

associated to the respective code that appears on the emergency

panel, and useful suggestions to solve the problem.

MESSAGE ON

DISPLAY

TYPE OF PROBLEM

SOLUTION

A01

Fire fails to ignite

Check the level of pellets in the hopper.
Check that the grate is properly inserted in its housing
and does not have any obvious unburnt incrustations;

A02

Fire extinguishes abnormally

Check the level of pellets in the hopper.
Check that the grate is properly inserted in its housing
and does not have any obvious unburnt incrustations;

A03

Pellet tank temperature exceeds foreseen
safety limit.
Structure has overheated due to reduced heat
dissipation

Or

Pressure switch triggered

Wait for the end of the cooling phase, cancel the alarm

and relight the stove placing the fuel load to minimum

(SETTINGS MENU - Pellet recipe) and increasing the room

fan speed. (V1-V5).

If the alarm persists, contact technical

support.

Check and clean the ENTIRE smoke duct.

Protect the outlet against any outside wind.

A08

Anomalous operation of smoke fan.

Check that the grate does not have visible unburnt

incrustations. If the alarm persists, contact technical

support.

A09

Smoke temperature too high or smoke probe
faulty

Wait for the end of the cooling phase, cancel the alarm

and relight the stove placing the fuel load to minimum

(section 5.4.4.) and increasing the room fan speed (section

5.4.5). If the alarm persists, contact technical support.


6.2. Exiting alarm condition

To reset the alarm hold the On/Off key down for a few moments: the

stove runs a check to assess whether the cause of the alarm persists or

not. In the first case the alarm will be displayed once again, in the

second case it will go to Off.
Only after the cause of the blockage has been permanently eliminated

can another attempt to relight the stove be made.

6.3. Normal shutdown (panel display: shutdown)

If the shutdown key is pressed or there is an alarm signal, the stove

enters the thermal shutdown phase foreseeing automatic execution of

the following phases:

 Pellet loading stops
 The room fan maintains set speed until smoke T reaches

100°C, then it automatically sets to minimum speed until

shutdown temperature is reached

 The smoke fan sets on maximum and stays there for a fixed

time of 10 minutes, at the end of which if smoke T has dropped

below 45°C (parameters can be displayed in the INFO menu) it

shuts down definitively, otherwise it sets to minimum speed

until such threshold is reached and then shuts down.