beautypg.com

MCZ Face User Manual

Page 49

background image

PELLET STOVES

Chapter 6

INSTALLATION AND USE MANUAL

page

49

Safety devices

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

6.4. BLACKOUT WITH STOVE LIT (panel display:

RELIGHTING AFTER BLACKOUT for 10’, then

LIGHTING)

In the case of no mains supply (BLACKOUT) the stove performs as

follows:

 Blackout less than 10”: it restores operation in progress;
 If there is no power supply for more than 10" when the stove is

lit or in the lighting phase, when the stove is powered again it

returns to the previous operating condition following the

procedure below:

1. It cools down by activating the smoke extractor at the

minimum for 10’ and proceeds to the next point;

2. It restores the stove to the operating condition before

the blackout.

During phase 1 the panel displays RELIGHTING AFTER BLACKOUT.
During phase 2 the panel displays Lighting.
If during phases 1-2 the stove receives commands from the panel (or

from the remote control) and therefore manually performed by the

user, the stove stops running blackout recovery and proceeds with

lighting or shutdown as the command requests.

If the power supply cut is LONGER THAN 10” with the stove in

shutdown phase, when the stove is powered again it restarts in

shutdown mode even if the smoke temperature has dropped below

45°C in the mean time. This last phase can be skipped by pressing key

0/1 (passes on to lighting) and by pressing it again (it recognises that

the stove is off).

Clean the grate “F” from ash and any incrustations which could

obstruct the air passage holes.