PELLET STOVES

Chapter 5

INSTALLATION AND USE MANUAL

page

43

Menu structure

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

5.4.6.2. Operating mode with external thermostat

and Eco-Stop

When the external thermostat and Eco Stop are active the stove

actuates the operating conditions described in para. 5.4.6.1, replacing

the command coming from the thermostat at the temperature read by

the probe, so that:

- When the temperature is achieved (thermostat contact open)

the decrease in ECO shutdown T" starts (default 10 minutes,

changeable (*) from inside the TECHNICAL MENU). During this

phase on the small panel display remains ON-ECO ACTIVE, but

the flame drops automatically be one power per minute until it

reaches P1 and stays there until the programmed "ECO

shutdown T" lapses and if the thermostat is still open, it moves

on to the shutdown phase.

Once the stove shutdown conditions are reached, on the panel the

words "OFF" and “ECO ACTIVE” alternate In this state if the room

temperature drops below that set (thermostat contract closed) the

stove relights without any delay.