beautypg.com

MCZ Face User Manual

Page 36

background image

PELLET STOVES

Chapter 5

INSTALLATION AND USE MANUAL

page

36

Menu structure

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

5.2.2. DETAILS OF TIMER OPERATION

1. The lighting time scrolls from 00.00 (midnight) to 23.50
2. If you change the lighting time and set a value later than the

shutdown time, the shutdown time automatically sifts to

lighting time + 10 min. to avoid operative errors.

3. The shutdown time may be chosen between lighting time +10

min. and 00.00 (midnight).

4. If a timer programme switches the stove off at 00.00

(midnight) on one day and another programme lights it at

00.00 (midnight) of the next day: the stove remains

continuously lit.

5. If the stove is lit and the timer active, it is possible to manually

shutdown the stove by pressing the OFF key; the stove shuts

down and shall relight automatically at the next time foreseen

by the timer

6. Equally in the stove off and timer active state, press the ON

key: the stove will light and shutdown at the time foreseen by

the active timer.

IMPORTANT NOTE

The stove takes about 15 minutes to light.
Take this into account when setting the start time.

Likewise, stove shutdown requires about 30 minutes,

during which the heat stored up by the stove is still

released into the room.
Keep this in mind for substantial fuel savings.

5.2.3. TIMER de-activation.

To de-activate the timer, access the menu again by means of button

OFF.

ATTENTION!
The TIMER function can be activated/deactivated

whether the stove is on or off.
If a timer programme has been activated, in the

initial screen the stove operating status

(on/off/start-up….) alternates with the word “TIMER

P01 active” (example)


This manual is related to the following products: