Problem possible cause remedy – MCZ Antares '03 User Manual
Page 49

PROBLEM
POSSIBLE CAUSE
REMEDY
The smoke extraction motor
does not work.
1. No electrical supply to the
stove.
1. The motor is broken.
1. Defective electronic board
2. Control panel broken.
1. Check the supply voltage and
the protection fuse.
2. Check the motor and
capacitor and replace if
necessary.
3. Replace electronic board.
4. Replace the control panel.
The convection air fan runs
continuously.
1. Temperature
sensor
defective or broken.
2. Fan
broken.
3. Check the operation of the
sensor and replace if
necessary.
4. Check the operation of the
motor and replace if
necessary.
Remote control does not
work.
1. Remote control batterie flat.
2. Remote
control
broken.
3. Replace
batteries.
4. Replace remote control.
In the automatic position the
stove always runs at full
power.
1. Room thermostat set to
maximum.
2. Temperature
sensor
defective.
3. Control panel defective or
broken.
4. Reset the thermostat
temperature.
5. Check the operation of the
sensor and replace if
necessary.
6. Check the panel and replace if
necessary.
The stove does not run.
1. Lack of electricity supply.
1. Pellet sensor in lockout.
1. Fuse
blown.
2. Pressure switch broken
(lockout indicated).
3. Smoke outlet or duct
blocked.
4. Check that the electric socket is
plugged in and that the main
switch is in position “I”.
5.
Clear lockout by resetting the
rear thermostat, replace the
thermostat if it happens
again.
6. Replace the fuse.
7. Replace the pressure switch.
8. Clean the smoke outlet and/or
smoke duct.
The operations marked in bold type must be
carried out by specialised MCZ personnel.
The manufacturer refuses to accept any
responsibility and the guarantee lapses if this
condition is not respected.