3.20 Alarm signals

In the event that a running problem occurs, as the stove is equipped with a computerised
monitoring system, it informs the user via the display of the nature of the fault and where it has
occurred.
The following table summarises the principal alarms which may be indicated.

Message on the display (8)

Type of problem

Solution

ALAR DEP FAIL
ALARM PRESSURE

Smoke extraction is low
because of obstruction of the
flue or back-pressure

Check and clean the WHOLE
flue system

ALAR FAN FAIL
ALARM FAN FAIL

The smoke fan is jammed / fan
speed too low

Replace the smoke fan

ALAR SOND FUMI
ALARM SMOKE PROBE

Smoke sensor short circuit

Replace smoke sensor

ALAR NO ACC
ALARM NO IGNITION

Occurs on first failed attempt at
lighting

Wait for the stove to restart
automatically. Check the level
of pellets in the hopper. Check/
replace the ignition sparkplug.

ALAR NO FIRE
ALARM NO FIRE

Occurs when the stove goes
out and when the temperature
of the smoke sensor is below
the preset threshold.

Derives from a failure to light –
see above.

ALAR FAIL SIC
ALARM THERMIC

The temperature of the pellet
hopper is above the preset
threshold ( 80-110°C )

Heat exchanger not working.
No voltage at exchanger.
Check the parameters of the
recipe used. Re-arm the
resettable thermostat.