World class 3000, Instruction manual, Intelligent field transmitter ift 3000 – Emerson Process Management 3000 User Manual
Page 51
![background image](/manuals/80614/51/background.png)
Instruction Manual
IB-106-300NH Rev. 4.2
July 2002
Rosemount Analytical Inc. A Division of Emerson Process Management
Installation 2-19
World Class 3000
JM7
I
V
MPS TERMINATION BOARD
MPS 3000 MULTIPROBE CALIBRATION GAS SEQUENCER (OPTIONAL)
L
E
N
LINE
VOLTAGE
J13 J14
J15
J16
J17 J18
J12
CAL
RET
HI
GAS
IN
CAL
NO
GAS
CAL
RET
HI
GAS
IN
CAL
NO
GAS
CAL
RET
HI
GAS
IN
CAL
NO
GAS
CAL
RET
HI
GAS
IN
CAL
NO
GAS
LOW
GAS
LOW
GAS
LOW
GAS
LOW
GAS
NC C NO NC C NO NC C NO NC C NO
L
N
L
N
LINE OUT
LINE IN
J10
J11
PROBE 1
PROBE 2
PROBE 3
PROBE 4
PROBE 1
PROBE 2
PROBE 3
PROBE 4
PROBE
1
SOLENOID
PROBE
2
SOLENOID
PROBE
3
SOLENOID
PROBE
4
SOLENOID
HIGH
GAS
SOLENOID
LOW
GAS
SOLE
NOID
PRESSURE SWITCH
SHIELD
SHIELD
RELAY –
RELAY +
TRIAC +
CAL RET
SHIELD
NO GAS
AD590 –
LO GAS
AD590 +
HI GAS
SHIELD
IN CAL
TRIAC –
SHIELD
SHIELD
STACK TC –
STACK TC +
PROBE MV –
PROBE MV +
PROBE TC +
PROBE TC –
INTELLIGENT FIELD
TRANSMITTER IFT 3000
ALWAYS DISCONNECT LINE VOLTAGE
FROM INTELLIGENT FIELD TRANSMITTER
BEFORE CHANGING JUMPERS.
LINE
VOLTAGE
SECTION
JUMPER
(INSTALL)
PROBE HEATER
VOLTAGE SECTION
JUMPER
(INSTALL)
100 V.A.C.
120 V.A.C.
220 V.A.C.
200 V.A.C.
240 V.A.C.
J1
J5
J6
J1
JM1
JM6
J2
J3
J4
J5
J6
J7
J8
J9
3D39122G REV
POWER SUPPLY BOARD
3D39513G
MICROPROCESSOR
BOARD
3D39120G REV
INTERCONNECT BOARD
JM3, JM7, JM2
JM8, JM7, JM1
JM6, JM5, JM2
JM4, JM5, JM2
JM6, JM5, JM1
NOT USED
REMOVE
JM9, JM10
JUMPER CONFIGURATION
E
N
L
LINE
VOLTAGE
NOT USED
5 CONDUCTOR SHIELDED CABLE
PER PROBE #16 AWG BY CUSTOMER
CURRENT/VOLTAGE
SELECTOR SWITCH
27270012
A
B
Figure 2-14. Wiring Layout for Complete IFT 3000 System with HPS (Sheet 2 of 2)