beautypg.com

World class 3000, Instruction manual – Emerson Process Management 3000 User Manual

Page 100

background image

Instruction Manual

Appendix A Rev. 3.8
July 2002

A-2 Appendices

Rosemount Analytical Inc. A Division of Emerson Process Management

World Class 3000

Table A-1. Specifications for Oxygen Analyzing Equipment.

1, 2

Probe lengths, nominal ..................................................................18 inches (457 mm), 3 feet (0.91 m), 6 feet

(1.83 m), 9 feet (2.74 m), or 12 feet (3.66 m),
depending on duct dimensions

Temperature limits in process

measurement area ............................................................50° to 1300°F (10° to 704°C)

Standard/current output..................................................................4-20 mA dc signal (factory set)
O

2

indication (Digital display

and analog output).............................................................0.1% O

2

or ±3% of reading, whichever is

greater using Rosemount calibration gases

System speed of response .............................................................less than 3 seconds (amplifier output)
Resolution sensitivity ......................................................................0.01% O

2

transmitted signal

HPS 3000 housing..........................................................................NEMA 4X (IP56)
Probe reference air flow .................................................................2 scfh (56.6 L/hr) clean, dry, instrument quality

air (20.95% O

2

), regulated to 5 psi (34 kPa)

Calibration gas mixtures .................................................................Rosemount Hagan Calibration Gas Kit Part No.

6296A27G01 contains 0.4% O

2

N

2

Nominal and

8% O

2

N

2

Nominal

Calibration gas flow ........................................................................5 scfh (141.6 L/hr)
HPS 3000 Power supply...............................................................100/110/220 ±10% Vac at 50/60 Hz
HPS 3000 Power requirement......................................................200 VA
HPS 3000 Ambient Operating Temperature ................................32° to 120°F (0° to 50°C)
Ambient operating temperature (Probe Junction Box) ...................300°F (150°C) max
Approximate shipping weights:

18 inch (457 mm) package................................................55 pounds (24.97 kg)
3 foot (0.91 m) package.....................................................60 pounds (27.24 kg)
6 foot (1.83 m) package.....................................................65 pounds (29.51 kg)
9 foot (2.74 m) package.....................................................72 pounds (32.66 kg)
12 foot (3.66 m) package...................................................78 pounds (35.38 kg)

1

All static performance characteristics are with operating variables constant.

2

Equipment ordered utilizing this document as reference will be supplied to the USA standard design. Custom-
ers requiring the EEC standard design should request the EEC documentation and utilize its ordering data.
Temperatures over 1000°F (537°C) may affect the ease of field cell replaceability.