beautypg.com

Load support vdc settings/info, Silent settings/info, 0 operation – Magnum Energy ME-RC Remote User Manual

Page 52

background image

45

©2013 Magnum Energy, Inc.

5.0 Operation

Load Support VDC appears on LCD.

PWR (green) LED is on solid, and

CHG (green) LED blinks. FAULT (red)

LED is off, and INV (green) LED could

be on or off.

FAULT

PWR

CHG

INV

Load Support VDC

Settings/Info..

Figure 5-15, Load Support VDC Mode

Load Support VDC – The inverter/charger is in the Load Support (Volts

DC) mode because an external DC source (solar, wind, etc.,) is providing

more current than needed—which causes the battery voltage to rise. The

inverter/charger reduces the incoming AC current in an effort to keep the

battery voltage from rising above the temperature-compensated SETUP: 04

Battery Type setting.

Info: The Load Support VDC feature operates in parallel with the

AC input to support the inverter loads and is only available on MSH

Series inverter/chargers. This feature is only active in Bulk, Absorb,

Float or EQ Charge modes and when the inverter is enabled (INV

LED is on); it is deactivated if the charger is in Charger Standby.

Silent appears on LCD. PWR (green)

LED is on solid, and CHG (green) LED

blinks. FAULT (red) LED is off, and

INV (green) LED could be on or off.

FAULT

PWR

CHG

INV

Silent

Settings/Info..

Figure 5-16, Silent Mode

• Silent – This displays at the end of the Absorption stage if Silent is

selected from the 09 Final Charge menu. In Silent mode, the charger is not

actively charging but does monitor the battery voltage. When the battery

voltage reaches the ReBulk setting (from SETUP: 09 Final Charge menu) the

charger will restart a Bulk and Absorb Charge cycle, and then transition back

into Silent mode at the end of the Absorb cycle.

Info: When the inverter is in Inverter Standby mode (charging and

pass-thru), the current is normally a positive value. However, in Load

Support AAC mode, the inverter amps reading is a negative number

to indicate how much current is being provided/removed from the

inverter batteries. The inverter batteries will continue to provide

current to assist the AC input current until the battery reaches 0.5

volts (12-volt systems), 1.0 volts (24-volt systems) , and 2.0 volts

(48-volt systems) above the SETUP: 02 LowBattCutOut setting.