3.0 Setup

• TECH: 04 Load Defaults – This menu restores all settings on the

inverter/charger, and any settings on accessories that are networked

and controlled by the inverter (i.e., ME-AGS-N) to the factory default

settings. To restore, press and hold the rotary SELECT knob for 5

seconds. Once restored, the display will show DEFAULTS LOADED. The

inverter/charger’s factory defaults are listed in Table 3-5.
Note: If a password (PIN) has been previously set, this menu will be

unavailable (i.e., locked). Refer to the TECH: 06 SETUP PIN section on

the next page for information on how to unlock this menu.

Info: For information on the factory default settings for any net-

worked accessory, refer to the owner’s manual for that accessory.

TECH

Press

Status...

04 Load Defaults

Rotate to

Press and hold

for 5 seconds

Status...

DEFAULTS LOADED

Factory defaults

are loaded and

display shows:

Figure 3-19, TECH: 04 Load Defaults Selection

Menu Items

Default Settings

SHORE Pushbutton

Shore Max = 30A*

SETUP Pushbutton

01 Search Watts

Search = 5W

02 LowBattCutOut

LBCO = 10.0 VDC (12-volt models),

20.0 VDC (24-volt models), or

40.0 VDC (48-volt models)

03 Absorb Time

Absorb Hrs = 1.5

04 Battery Type

BatType = Flooded

05 Charge Rate

Max Charge = 80%

06 VAC Dropout

Dropout = 80 VAC*

(150 VAC for export models)

07 Power Save

PwrSave = 15min

08 Screen Setup

Contrast =100%

Brightness =50%

09 Final Charge

Final = Multi

10 Power Up Always

Pwr Up = NO

* - If using with a MSH4024RE model inverter (which has two AC inputs),

both AC inputs will have the same setting (i.e., in example above, both

the AC1 and AC2 inputs would have a Shore Max setting of 30A and a VAC

Dropout setting of 80 VAC).

Table 3-5, ME-RC’s Inverter/Charger Default Settings