0 setup – Magnum Energy ME-RC Remote User Manual
Page 38
31
©2013 Magnum Energy, Inc.
3.0 Setup
• TECH: 04 Load Defaults – This menu restores all settings on the
inverter/charger, and any settings on accessories that are networked
and controlled by the inverter (i.e., ME-AGS-N) to the factory default
settings. To restore, press and hold the rotary SELECT knob for 5
seconds. Once restored, the display will show DEFAULTS LOADED. The
inverter/charger’s factory defaults are listed in Table 3-5.
Note: If a password (PIN) has been previously set, this menu will be
unavailable (i.e., locked). Refer to the TECH: 06 SETUP PIN section on
the next page for information on how to unlock this menu.
Info: For information on the factory default settings for any net-
worked accessory, refer to the owner’s manual for that accessory.
TECH
Press
Status...
04 Load Defaults
Rotate to
Press and hold
for 5 seconds
Status...
DEFAULTS LOADED
Factory defaults
are loaded and
display shows:
Figure 3-19, TECH: 04 Load Defaults Selection
Menu Items
Default Settings
SHORE Pushbutton
Shore Max = 30A*
SETUP Pushbutton
01 Search Watts
Search = 5W
02 LowBattCutOut
LBCO = 10.0 VDC (12-volt models),
20.0 VDC (24-volt models), or
40.0 VDC (48-volt models)
03 Absorb Time
Absorb Hrs = 1.5
04 Battery Type
BatType = Flooded
05 Charge Rate
Max Charge = 80%
06 VAC Dropout
Dropout = 80 VAC*
(150 VAC for export models)
07 Power Save
PwrSave = 15min
08 Screen Setup
Contrast =100%
Brightness =50%
09 Final Charge
Final = Multi
10 Power Up Always
Pwr Up = NO
* - If using with a MSH4024RE model inverter (which has two AC inputs),
both AC inputs will have the same setting (i.e., in example above, both
the AC1 and AC2 inputs would have a Shore Max setting of 30A and a VAC
Dropout setting of 80 VAC).
Table 3-5, ME-RC’s Inverter/Charger Default Settings