9
©2013 Magnum Energy, Inc.
3.0 Setup
3.2
Remote Feature to Inverter Compatibility
The ME-RC has many settings and is designed to work with the standard
features in your Magnum inverter—and/or other Magnum devices (i.e., ME-
AGS-N or ME-BMK). The ME-RC communicates with your inverter to allow
the set up and enabling of these standard features. However, when the ME-
RC is released with new software, some of the features and functionality in
the remote may not be available in an inverter or networked accessory that
has an earlier software level. In this case, the setting is not recognized and
will not function. Use the steps below to help you determine which ME-RC
(Revision 2.8) menus/features are compatible with your inverter.
1. Go
to:
http://www.magnumenergy.com/Service/Compatibility.htm
to
determine your inverter’s compatibility level (L1, L2, L3, or L4).
2. Use Table 3-1 to determine which ME-RC features/settings you want to
use, and what inverter compatibility level is required (see the “Inverter
Model/Level Required” column in Table 3-1).
3. If your inverter compatibility level is the same or greater than the level
required, your inverter can support the setting/feature you want.
4. If your inverter does not have the required compatibility level for a fea-
ture/setting you want, contact Magnum Energy for a software upgrade.
Info: The ME-RC compatibility matrix below is also available online to
download/print as a single page document and to enter user settings.
http://www.magnumenergy.com/Service/Compatibility.htm
.
Table 3-1, ME-RC (Revision 2.8) Compatibility Matrix
Button
FEATURES/SETTINGS
Inverter
Model/
Level
Required
Default
Setting
Menu
Heading
Menu Item
Selections/
Adjustments Range
SHORE
Shore Max
5 - 60A
≥Level 1
[1]
30A
AGS
01 AGS
Control
AGS= OFF, Enable, Test, Enable
w/QT (Set Time)
≥Level 1
OFF**
02 AGS
Status
AGS: Read only display
≥Level 1
Read Only
03 Run
Time Hour
Run Time= 0.5 - 25.5 Hours
≥Level 1
2.0 Hrs
04 Start
Temp F
Start Temp= OFF, Ext Input, 65 - 95F
≥Level 1
OFF
05 Start
Volts
Start VDC= OFF, 10.0 - 12.2*
≥Level 1
11.0
06 Set
Time
Hour= 01:xxx-12:xxx
≥Level 1
12:00A
Minute= xx:00x-xx:59x
AM-PM= xx:xxA-xx:xxP
07 Quiet
Time
Quiet=
OFF,
9PM- (7AM/8AM/9AM),
(10PM/11PM) - 8AM
≥Level 1
OFF