beautypg.com

0 setup – Magnum Energy ME-RC Remote User Manual

Page 37

background image

©2013 Magnum Energy, Inc.

30

3.0 Setup

TECH

Press

Status...

01 Temperatures

Rotate to

Press to select

Rotate to

desired

display:

Options: BTS:, Tfmer:, FETs:, AGS:

Figure 3-16, TECH: 01 Temperatures Display

• TECH: 02 Revisions – Displays the revisions of the devices that are

connected to the Magnum network. Rotate the SELECT knob to scroll

through the revisions. The following devices display revisions (if

connected to the remote): inverter, remote, AGS, BMK, and router.

TECH

Press

Status...

02 Revisions

Rotate to

Press to select

Rotate to

desired

display:

Options: Inverter:, Remote:, AGS:, BMK:, Router:

Figure 3-17, TECH: 02 Revisions Display

Info: The BMK, AGS, and the remote accessories may display a

“0.0” revision. Either the accessory is not installed, there is no com-

munication because of a bad or miswired network cable, the device

is not powered, or the device is bad.

• TECH: 03 Inverter Model – This read only menu displays the model

number of the connected inverter.

TECH

Press

Status...

03 Inv Model

Rotate to

Press

Status...

Model: ####

Display shows

connected inverter:

Figure 3-18, TECH: 03 Inv Model Display

Info: When “Model: UNKNOWN” is displayed, the remote is unable

to determine the inverter model. This happens when the remote is

connected to a later/newer inverter model not recognized by an older

remote. All remote menu selections and features that are available

in the inverter will function normally.

Info: The revision may display “0.0” for several reasons. Either the

inverter is not installed, there is no communication due to a bad or

miswired network cable, or the inverter is not powered or is bad.