Single in / dual out wiring, Direct from inverter (inverter loads), Blue – Magnum Energy MS Series User Manual

Page 42

background image

©

2012 Magnum Energy, Inc.

Page 33

Installation

Main Panel

(Utility Power/Generator Input)

MS2000-15B/

MS2000-20B Inverters

AC Terminal Block

(AC input and output wiring)

SINGLE IN / DUAL OUT wiring

Direct from inverter

(Inverter Loads)

120

VAC

120

VAC

ON

OFF

ON

OF

F

ON

OF

F

ON

OF

F

ON

OF

F

ON

OF

F

ON

OF

F

ON

OF

F

ON

OF
F

ON

OF

F

ON

OF
F

ON

OF
F

ON

OF
F

30

.

Maximum 30-amp breaker

(single pole) required to

inverter AC input.

In mobile installations: neutral is typically not

connected to ground in the main panel.

AC HOT

.

1 OUT

Has optional 15-amp or 20-

amp branch-rated circuit

breakers (on side of unit).

ORANGE

BLUE

AC HOT

.

2 OUT

AC NEUT OUT

GREEN

AC GROUND (x2)

AC GROUND

WHITE

AC NEUT IN

AC HOT IN

BLACK

.

WHITE w

.

/ BLACK

.

WHITE w

.

/ BLACK

AC NEUT OUT

Figure 2-15, AC Wiring for MS2000-15B/-20B Models