Sub-panel and outlets (inverter loads), Single in / single out (30a) wiring – Magnum Energy MS Series User Manual
Page 41

Page 32
©
2012 Magnum Energy, Inc.
Installation
Main Panel
(Utility Power/Generator Input)
MS2000 Inverter
AC Terminal Block
(AC input and output wiring)
SINGLE IN / SINGLE OUT (30A) wiring
Sub-Panel and Outlets
(Inverter Loads)
120
VAC
120
VAC
ON
OFF
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
30
..
Maximum
..
30 amp breaker
(single pole)
required to
inverter AC input
In mobile installations: neutral is typically not
connected to ground in the main panel.
ON
OF
F
ON
OF
F
ON
OFF
BLACK
AC HOT IN
WHITE
AC NEUT IN
GREEN
AC GROUND
AC GROUND
.
WHITE w
.
/ BLACK
AC
.
NEUT
.
OUT
.
BLUE
AC HOT
.
1 OUT
Figure 2-14, AC Wiring for MS2000 Models