beautypg.com

Installation – Magnum Energy MS Series User Manual

Page 40

background image

©

2012 Magnum Energy, Inc.

Page 31

Installation

2.5.8

AC Wiring Confi guration (MS2000 models)

The following table provides the different wiring confi gurations for installing and connecting the

AC conductors to and from MS2000 model inverters (see Figures 2-14 and 2-15 for installation

diagrams showing these confi gurations).

Table 2-4, AC Input/Output Wiring Confi gurations (MS2000 models)

SI/SO (30A)

Single In/

Single Out

(30A)

SI/DO

Single In/

Dual Out

AC Source

1

Required

120 VAC @

< 30 amps

120 VAC @

< 30 amps

@ < 15 amps per

leg (-15B models);

or < 20 amps per

leg (-20B models).

Reason to

Use

Have an 120

VAC source

that is < 30

amps.

Requires

a separate

inverter

sub-panel.

Do not want to

install a separate

inverter sub-panel.

Inverter pass-thru

capability limited

by model used.

Appropriate

Models

MS2000

MS2000-15B

MS2000-20B

Maximum

Input

Breaker

Required

-

Minimum

Wire Size

30A

(single pole)

-

#10 AWG

(In & Out)

-15B models:

30A (single pole);

-20B models:

30A (single pole)

-

#10 AWG (In)

#12 AWG x2 (Out)

Maximum

Inverter

Pass-thru

capacity

3600W

(30A @

120 VAC)

-15B models:

15A/leg

(30A max.);

-20B models:

20A/leg

(30A max.)

Wiring

Diagram

Figure 2-14

Figure 2-15

This manual is related to the following products: