Internal Fault - The inverter continually monitors several inter-

nal components and the processor communications. If a condition

occurs that doesn’t allow proper internal operation, the inverter

will shut down to protect itself and the connected loads. The

inverter will need to be reset to start operating.

Table 5, Inverter Battery Turn On/Off Levels

* - adjustable with remote

Inverter Startup

ON/OFF Switch - The inverter can be turned on and off by lightly

pressing and releasing the Power ON/OFF switch on the front of the

inverter. When the inverter is fi rst connected to the batteries, or when

its automatic protection circuit has turned the inverter off, the ON/OFF

switch will need to be pressed to start the unit. Once the inverter

has been turned on, pressing the Power ON/OFF switch alternately

turns the inverter on and off.

WARNING: The Power ON/OFF control switch does not

turn on or off the charger feature. If AC power (utility or

generator) is connected and qualifi ed on the AC input,

this AC power will also be available on the AC output

and is not controlled by the Power ON/OFF switch.

Status LED Indicator - The status indicator is a green LED (Light

Emitting Diode) that provides information on the operational mode of

the inverter. Watch this indicator for at least 10 seconds to determine

the inverter’s operational condition from the information below:

Inverter Mode

Off - Indicates the inverter is off; there is no AC power from

the inverter, utility, or generator at the inverter’s output

terminals.
Blinks On (once every second) - The inverter is on and is

using energy from the battery. The inverter is either provid-

ing full power to the loads connected to the inverter, or it’s in

Search Mode and ready to supply AC power to the connected

loads.

3.0 Operation

29

Inverter Battery

Turn On/Off

Levels

Inverter Model

MM612AE

MM1512AE

MM1524AE

HBCO

>15.8 VDC

>15.8 VDC

>31.6 VDC

HBCI

15.5 VDC

15.5 VDC

31.0 VDC

LBCI

≥12.5 VDC

≥12.5 VDC

≥25.0 VDC

LBCO*

(one minute delay)

10.0 VDC

(9.0 - 12.2 VDC

)

10.0 VDC

(9.0 - 12.2 VDC

)

20.0 VDC

(18.0 - 24.4 VDC)

LBCO

(immediate)

8.5 VDC

8.5 VDC

17.0 VDC