beautypg.com

Magnum Energy MM-AE Series User Manual

Page 28

background image

©

2010 Magnum Energy, Inc.

22

3. Prior to turning on the inverter, make sure all connected loads (e.g.,

appliances) are switched OFF or disconnected from the AC outlets.

4. a. If a remote switch is connected, press the ON/OFF switch to

turn the inverter on.
b. If there is not a remote switch connected, lightly press and

release the inverter’s ON/OFF power switch — located on the top of

the inverter — to turn the inverter on.
Verify the inverter’s status indicator is blinking – indicating the in-

verter is providing AC power.

5. Check the output voltage of the inverter by connecting a true

RMS multimeter to the outlets powered by the inverter. Verify the

voltage is 120 VAC +/- 5 VAC. If not using a true RMS meter the

output AC voltage could indicate from 90 to 130 VAC, depending on

the battery voltage.

6. Turn on or connect a load to the outlets and verify it comes on.

Continue to keep the load connected and turned on.

7. Press the remote ON/OFF switch to turn the inverter off. If the

remote is not used, press and release the inverter’s ON/OFF power

switch to turn the inverter off. The inverter’s status indicator and the

connected load should go off.

8. Apply AC power to the inverter’s AC input. After the AC input power

is qualifi ed (approximately 15 seconds), the incoming AC power will

transfer through the inverter to the inverter’s AC output and power

the connected load. Verify the inverter’s status indicator and the

connected load comes on.

9. Even though the connected load is on, the inverter is currently

disabled/off. Press the remote’s ON/OFF switch (or press and re-

lease the ON/OFF power switch on the inverter) to enable/turn on

the inverter.

10. Disconnect the incoming AC power to the inverter. Verify the con-

nected load remains on, but now is powered by the inverter.

If the inverter passes all the steps, the inverter is ready for use.
If the inverter fails any of the steps, refer to the Troubleshooting

section.

2.0 Installation

This manual is related to the following products: