beautypg.com

Magnum Energy MM-AE Series User Manual

Page 24

background image

©

2010 Magnum Energy, Inc.

2.0 Installation

18

The AC wires inside the AC compartment are #16 AWG with a tem-

perature rating of 105° C. All AC connections should be made using

an approved connector for your application (e.g., split bolt, twist-on

wire connectors, etc.). Ensure the wire connectors used are rated for

the size and number of wires you are connecting.
After connecting the wires together, gently pull on the wires to ensure

they are securely held together. In a proper connection, no bare wire

should be exposed

.

Info: Per UL certifi cation, non-metallic sheathed cable

(i.e., Romex™) or an SO fl exible cord with listed strain

reliefs are allowed to be used to connect to the inverter;

conduit connections are not allowed.

After all AC wiring in the inverter is complete (and before reattach-

ing the AC access cover), ensure all connections are correct and

secure.

Table 3, Wire Color to AC Wire Connection

AC Wiring Connections
For all hardwired inverter models, the AC input and output wiring is

performed in the AC wiring compartment. This compartment is located

on the top panel (see Figure 2, Item 8). If installed, remove the two

Phillips screws on the cover to access the AC wiring compartment

and locate the inverter’s AC wiring. There is a label located in the AC

access compartment which gives information on which wires are used

for the AC input and output. You can also refer to Table 3 to match

the inverter’s AC wires to the appropriate AC wire connection.

AC Wire Size and Overcurrent Protection

The AC input and output wiring must be sized

per the NEC and

local

electrical safety code requirements

to ensure the wire’s ability to

safely handle the inverter’s

maximum load current. After determining

the proper AC wire sizes, the inverter’s AC input (unless you are using

a fl exible cord) and output wires are required to be protected against

overcurrent and have a means to disconnect the AC circuits.

Wire color (label)

Wire connection

AC IN

Black (HOT IN)

Hot In

White (NEUT IN)

Neutral In

AC OUT

Red (HOT OUT)

Hot Out

White with black

stripe (NEUT OUT)

Neutral Out

AC Ground

Green (GROUND)

AC IN & AC OUT Ground