Yaskawa DSD 406 User Manual
Page 70

4
Maintenance
66
Troubleshooting Guide
3/21/96
Fault/Error
Possible Causes &
Code
Fault/Error Name
Corrective Actions
Table 3. Troubleshooting Guide – Continued
260
261
262
263
264
265
Iteration Time-Out
Out of Sequence
Byte Time Out
Wrong File Type
Null Block Expected
User Canceled
YMODEM transfer is stopped. The drive
has tried to send or receive a character and
failed to do so within a specific timeout
period.
➊
Verify that the serial cables are attached
properly between the source PC and the
drive.
❷
Verify that the PC has the correct serial
communications settings for
communications with a drive.
YMODEM transfer is stopped. YMODEM
protocol has been violated by an out of
sequence block.
➊
Cancel and try to start over again.
YMODEM transfer is stopped.
Same corrective actions as 260.
YMODEM transfer is stopped. The drive
was sent a file whose file extension was not
recognized. The drive will accept either a
.PRG file or a .PAR file.
➊
Cancel and try again with a valid file
name.
YMODEM transfer is stopped. The
YMODEM protocol has been violated. A
null block was expected but never received.
➊
Re-initialize up load procedures on the
YMODEM software and the drive and try
again.
YMODEM transfer is stopped. A user has
aborted the file transfer from the PC.
➊
Start again if desired.