beautypg.com

E.if.0 – Yaskawa DSD 406 User Manual

Page 50

background image

3

Operation

46

3/21/96

e.if.0

DATA

RED

Error Handling/Reporting

❏ Press the DATA/FCTN key to enter the "Data" level for function # 801.

The data indicator is GREEN and the error code last modified with function
# 801 will be in the SCDU display. The SCDU displays error code # 13
(illegal instruction) initially after power up:

❏ Use the

and

keys to select the error code entry in the Disposition List

that is about to changed/viewed. For example, if the disposition for error
code # 102 (Numeric Underflow) is to be modified, press the

key until the

SCDU display changes to:

GREEN

DATA

102

❏ Press the ENTER key when the desired error code is displayed on the

SCDU. The data indicator changes from GREEN to RED, and the SCDU
display changes as well to a format of ‘E.xF.y’. The ‘E’ and ‘F’ are
abbreviations for Error and Fault respectively. The ‘x’ and ‘y’ will be either
‘1’ or ‘0’ to indicate which list will record the error. For example, if the
display is ‘E.1F.1’, the error is recorded in both lists. If the display is
E.0F.1’, the error is recorded in the fault list, but not in the error list. If the
display is ‘E.0F.0’, neither list records the error. In the example above, the
factory set default disposition for a Numeric Underflow (code # 102) is to
record the error in the Error List, but not in the Fault List. In this case, the
SCDU display is:

GREEN

DATA

13