Yaskawa VS-616G5 Series Revision F Programming Manual User Manual
Page 58
V/f
V/f w/PG Open Loop
Vector
Flux
Vector
58
VS-616G5 Programming Manual
Section E: Motor Parameters
E1 V/F Pattern
For 460V class units, the value is twice that of 230V class units. For 575V class units the value is 2.5 times the 230V value.
For 460V class units, the value is twice that of 230V class units. For 575V class units the value is 2.5 times the 230V value.
V/F Patterns for Inverter Capacity 55 ~ 300kW for 200V Class
Parameter
Name
Unit
Factory Setting
E1-03
V/f Pattern Selec-
tion
–
0
1
2
3
4
5
6
7
E1-04
Max. Output Fre-
quency
Hz
50.0
<21>
60.0
60.0
72.0
<21>
50.0
<21>
50.0
<21>
60.0
60.0
E1-05
Max. Voltage
V
230.0
230.0
230.0
230.0
230.0
230.0
230.0
230.0
E1-06
Max. Voltage Fre-
quency
Hz
50.0
<21>
60.0
50.0
<21>
60.0
50.0
<21>
50.0
<21>
60.0
60.0
E1-07
Mid. Output Fre-
quency
V
2.5
<21>
3.0
3.0
3.0
25.0
<21>
25.0
<21>
30.0
30.0
E1-08
Mid. Output Fre-
quency Voltage
V
13.8
<21>
13.8
<21>
13.8
<21>
13.8
<21>
40.2
<21>
57.5
<21>
40.2
<21>
57.5
<21>
E1-09
Min. Output Fre-
quency
Hz
1.3
<21>
1.5
1.5
1.5
1.3
<21>
1.3
<21>
1.5
1.5
E1-10
Min. Output Fre-
quency Voltage
V
6.9
6.9
6.9
6.9
5.7
<21>
6.9
5.7
<21>
6.9
V/F Patterns for Inverter Capacity 55 ~ 300kW for 200V Class (Continued)
Parameter
Name
Unit
Factory Setting
E1-03
V/f Pattern Selec-
tion
–
8
9
A
B
C
D
E
F
E1-04
Max. Output Fre-
quency
Hz
50.0
<21>
50.0
<21>
60.0
60.0
90.0
<21>
120.0
<21>
180.0
<21>
60.0
E1-05
Max. Voltage
V
230.0
230.0
230.0
230.0
230.0
230.0
230.0
230.0
E1-06
Max. Voltage Fre-
quency
Hz
50.0
<21>
50.0
<21>
60.0
60.0
60.0
60.0
60.0
60.0
E1-07
Mid. Output Fre-
quency
V
2.5
<21>
2.5
<21>
3.0
3.0
3.0
3.0
3.0
3.0
E1-08
Mid. Output Fre-
quency Voltage
V
17.2
<21>
23.0
<21>
17.2
<21>
23.0
<21>
13.8
<21>
13.8
<21>
13.8
<21>
13.8
<21>
E1-09
Min. Output Fre-
quency
Hz
1.3
<21>
1.3
<21>
1.5
1.5
1.5
1.5
1.5
1.5
E1-10
Min. Output Fre-
quency Voltage
V
8.0
<21>
10.3
<21>
8.0
<21>
12.6
<21>
6.9
6.9
6.9
6.9